Mini Bench-top Ceramic Membrane Filtration Separation Equipment, Microfiltration, ultrafiltration & nanofiltration, 6-12 L/H

This equipment can be applied to microfiltration, ultrafiltration, nanofiltration, membrane selection according to the molecular weight of the substance, suitable for laboratory miniaturization research, and solves the large volume and processing capacity of traditional ceramic membrane separation equipment. Room use problems.

Process principle

Ceramic membrane filtration separation technology is a liquid separation process in the form of “cross-flow filtration”. The raw material liquid flows at a high speed in the membrane tube, and the clarified permeate containing the small molecular component is permeable to the membrane in the direction perpendicular to the pressure, and the turbid concentrate containing the macromolecular component is trapped by the membrane, thereby separating the fluid. Concentration, purification purposes. 

Features

  • Can withstand high temperatures, suitable for filtration in high temperature processes, chemically stable
  • High mechanical strength, wide pH tolerance, acid resistance, alkali resistance, resistance to organic solvents and strong oxidants
  • Long service life, low overall equipment cost and high cost performance
  • High multiples, reducing water usage and reducing wastewater discharge
  • Sterilize the membrane module with high temperature steam, suitable for sterilization filtration

Classification

Main component schematic

 

ABOUT TAMI TUBULAR CERAMIC MEMBRANE

The tubular ceramic membrane imported from France is made of completely high purity materials. The geometric shape is diverse and meets the needs of users.

Tubular ceramic membranes are used in different separation ranges: microfiltration, ultrafiltration, and fine ultrafiltration. 

Standard length specifications of the membrane:

Φ10mm:250/600/1201mm

Φ20mm:1178mm

Φ25mm:580/1178mm

Φ41mm:1020mm

Membrane molecular weight

Fine ultrafiltrationUltrafiltrationMicrofiltration
1kg/mol15kg/mol0.14um
3kg/mol50kg/mol0.20um
5kg/mol150kg/mol0.30um
8kg/mol300kg/mol0.45um
 0.80um
 1.4um

 Membrane application field

    

Membrane select

System Overview
This equipment can be applied to microfiltration, ultrafiltration, nanofiltration, membrane selection according to the molecular weight of the substance, suitable for laboratory miniaturization research, and solves the large volume and processing capacity of traditional ceramic membrane separation equipment. Room use problems.

Application
Food and beverage      Fermentation       Pharmaceutical            Natural product
Chemical industry        Chemical synthesis       Environmental protection and water treatment
New material

Features

Desktop MINI-style integrated design

  1. Original design of the desktop MINI solves the traditional problem of large volume of ceramic membrane experimental equipment
  2. Easy to place on the desktop, easy to operate
  3. Highly integrated design, compact and compact
 Imported ceramic membrane element

  1. Imported original ceramic film, customized film for imported original
  2. Scope of application: microfiltration, ultrafiltration, nanofiltration
  3. Filled with LCM-MS high-quality membrane shell
 Membrane shell

  1. PH range: 0-14
  2. Model: LCM-MS series high-quality membrane shell
  3. Material: AISI 316L
  4. Connection method: clamp quick release connection
 Material standard

  1. Material contact: Material AISI 304
  2. Non-contact material part: Material AISI 304
  3. Pipe: Sanitary seamless stainless steel pipe
  4. Valves: food grade sanitary ball valve, diaphragm valve
 New generation control system

  1. HSSP standard spray process chassis
  2. 7-inch capacitive high-resolution touch screen
  3. Temperature and pressure use medical grade sensors
  4. New generation LCM-Control control system, online monitoring data and control

Specifications

SN

ITEM NAME

SPECIFICATIONS

BASIC

1.

model

MCS-Mini

2.

Process capacity

6-12 L/H

3.

Minimum circulation volume

1L

4.

Anti-solvent

Resistant to organic solvents

5.

temperature range

0-121 ℃(Steam sterilization)

6.

PH range

0-14

7.

Working pressure

0-6 bar

8.

Maximum tolerance

10 bar

9.

Heat Exchanger

Tube and tube heat exchanger

10.

Material circulation tank

10 L

11.

Power unit

Imported brand centrifugal pump

12.

Valve, flow meter

Sanitary Quick Install Valve, Glass float flowmeter

13.

pipeline

Medical grade seamless 304 stainless steel tube

Membrane Element

1.

Membrane type

Imported ceramic membrane

2.

Filter range

Microfiltration, ultrafiltration, nanofiltration

3.

Membrane pore size

200D-1.2μm

4.

Membrane length

500mm

5.

Membrane load capacity

1pc

6.

Single membrane area

0.025㎡-0.11㎡

7.

health standard

FDA Standard Certification, 3-A

Membrane Shell

1.

Quantity

1 pc

2.

model

LCM-MS series high quality ceramic membrane shell

3.

Material

AISI 316L

Control System

1.

Electrical control cabinet

HSSP standard spray process chassis, beautiful and elegant, electrical components adopt Schneider Electric

2.

touch screen

7-inch capacitive high-resolution touch screen

3.

Thermometer sensor

Sanitary temperature sensor

4.

Pressure Sensor

Sanitary pressure sensor

5.

Software system

LCM-Control version 1.0 control system, equipped with temperature, pressure sensing, pump start, stop and frequency control data curve, recording and alarm functions.

Others

1.

voltage

AC220v、50hz

2.

rated power

AC220v/1.6kw

3.

Size (L * X * H)

565X395X715

4.

weight

35kg

Optional

1

Materials, heat exchangers, flow meters, valves, pumps, etc. can be specially customized according to different environments

2

Semi-automatic, fully automatic control system can be customized according to user needs

3

Remote control, mobile iPad control system customized according to user needs

    Get Quote Form

    Your Name:

    Your Email:

    Company Name (Organization):

    Message:

    Scroll to Top