Labfreez FD-P5 Process Freeze Dryer for Vaccine Video, with Stoppering & CIP system.
Features:
- Meets with GMP standard;
- Meets with CE/ISO standard;
- SIP+CIP is optional;
- Material made by SS316L to meets with pharmaceutical standards.
- Well documented included IQ/PQ/OQ/FAT and etc.
Parameters:
MODEL | Unit | FD-P1 | FD-P2 | FD-P3 | FD-P5 |
dry area | M2 | 1.15 | 2.16 | 3.24 | 5.2 |
Feed amount (material thickness 10mm) | L | 10 | 20 | 30 | 50 |
Number of shelves | Qty | 4+1 | 4+1 | 6+1 | 7+1 |
shelf size | cm | 60*48 | 60*90 | 60*90 | 75*100 |
shelf spacing | mm | 80 | 80 | 80 | 80 |
Temperature control range | ℃ | -50°C ~ +70°C | -50°C ~ +70°C | -50°C ~ +70°C | -50°C ~ +70°C |
Water vapor condensation | Kg/B | ≥20 | ≥40 | ≥60 | ≥100 |
Catch reservoir temperature | ℃ | ≤-75 | ≤-75 | ≤-75 | ≤-75 |
cooling method | – | Water Cooling | Water Cooling | Water Cooling | Water Cooling |
defrosting method | – | Water soaking | Water soaking | Water soaking | Water soaking |
ultimate vacuum | pa | ≤1 | ≤1 | ≤1 | ≤1 |
Installed power | kw | 18 | 21 | 24 | 25 |
Dimensions (L*W*H) | cm | 250*110*200 | 250*130*200 | 280*120*250 | 400*150*250 |
Φ22 vial volume | Pcs | 2460 | 4608 | 6912 | 11648 |
Φ16 vial volume | Pcs | 4788 | 8960 | 13440 | 22540 |
Total Weight | kg | 1500 | 2600 | 2800 | 5000 |
Pure steam consumption | kgh | 60 | 80 | 100 | 130 |
Injection water volume/pure water | 1/min | 60 | 75 | 90 | 120 |
Model | Unit | FD-P10 | FD-P15 | FD-P20 | FD-P30 | FD-P50 |
dry area | M2 | 10.5 | 15 | 20.2 | 29.7 | 51.3 |
Feeding amount (material thickness 10) | L | 100 | 150 | 200 | 300 | 500 |
Number of shelves | Qty | 7+1 | 10+1 | 11+1 | 11+1 | 19+1 |
shelf size | cm | 99*152 | 99*152 | 121*152 | 150*180 | 150*180 |
shelf spacing | mm | 80 | 80 | 80 | 80 | 80 |
Temperature control range | ℃ | -50°C ~ +70°C | -50°C ~ +70°C | -50°C ~ +70°C | -50°C ~ +70°C | -50°C ~ +70°C |
Water vapor condensation | kgB | ≥300 | ≥300 | ≥400 | ≥600 | ≥1000 |
Catch reservoir temperature | ℃ | ≤75 | ≤-75 | ≤-75 | 75 | ≤75 |
cooling method | – | Water Cooling | Water Cooling | Water Cooling | Water Cooling | Water Cooling |
defrosting method | – | Water soaking | Water soaking | Water soaking | Water soaking | Water soaking |
ultimate vacuum | pa | ≤1 | ≤1 | ≤1 | ≤1 | ≤1 |
Installed power | kw | 58 | 80 | 96 | 120 | 150 |
Dimensions (L*W*H) | Cm | 670*180*350 | 650×230×360 | 740*210*370 | 650*240*380 | 750*240*460 |
Φ22 vial volume | Pcs | 22932 | 34398 | 45045 | 64449 | 111321 |
Φ16 vial volume | Pcs | 42966 | 644149 | 84843 | 129789 | 224181 |
Total Weight | kg | 7000 | 8000 | 11000 | 15000 | 26000 |
Pure steam consumption | kgh | 200 | 230 | 280 | 380 | 500 |
Injection water volume/pure water | 1min | 160 | 200 | 230 | 280 | 400 |
Parts Introduction
German Bitzer Compressor | |
Edwards Vacuum Pump (England) | |
Leybold Vacuum Germany | |
Germany’s Wilo pump | |
Danish Grundfos circulation pump | |
Danfoss solenoid valve | |
Danfoss expansion valve | |
|
DANFOSS Pressure Gauge & Controller |
|
Emerson Oil Separator |