Industry Circulation Chiller
Rapid Cooling For The Liquid, Widely Used In Petrochemical, Medical, Pharmaceutical, Biochemical And Freeze-Dried, Military And Other High-Tech Industries.
Features
- Wide cooling temperature range, can meet different requirements
- Used environmental protection refrigerants
- Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK. Bitzer, Copeland, Hanbell, fusheng; Plate heat exchanger, Small volume, High efficiency
- Top imported cold controller(DANFOSS pressure controller, balance valve, expansion valve, solenoid valve, filter drier, Emerson oil separator, ALCO liquid mirror, check valve, etc.)
- Generator cooling water circuit use intermediate heat exchanger, improve system reliability and safety.
- DANFOSS electronic expansion valve, high precision control;
- Adopt Siemens PLC S7-200/300, touch screen, automatic control, temperature curve display, temperature record U disk, fault alarm;
- Large cooling capacity adopts semi-hermetic screw compressor, electronic expansion valve control, high efficiency and energy saving;
- Offer machine installation and system test, users only need to finish the installation of refrigerant and cooling water;
- Factory testing: each refrigerating unit is on load test of not less than 12 hours in the factory.
Technical Parameters:
Common |
|
Compressor |
Standard: HANBELL screw compressor |
Operation Panel |
7-inch color touch screen display, temperature curve record, data export to excel format. |
Control System |
Standard: Single-chip microcomputer controller; Stepping control; Set temperature difference of refrigeration on & off. |
Closed |
The whole system is a full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, |
Circulation pump |
Standard: Direct type magnetic pump |
Evaporator |
Standard: Braze welding plate heat exchager (BPHE) |
Condenser |
Shell and tube type water cooled condenser |
Intermediate heat exchanger |
KAORI Plate heat exchanger |
Dry Filter |
Emerson |
Drying filter core |
Emerson |
Expansion tank |
Emerson |
FDF |
Emerson |
Oil separator |
Emerson |
Pressure protector |
Emerson |
Reservoir |
Standard: RSP Optional: Emerson |
Sight glass |
Standard: SANHUA Optional: Danfoss |
Refrigeration ball valve |
Standard: SANHUA Optional: Danfoss |
Electric |
Schneider AC contactor, Schneider intermediate relay |
Refrigerant |
R404A |
Secondary refrigerant |
No corrosive liquid, ethanol water, ethylene glycol aqueous solution, heat transfer oil etc. |
Safety protection |
High pressure protect; Water supply cut-off protection; Over-current protection; Leakage protection; |
Level Indicator |
Adpot glass liquid level indication |
Piping material |
SUS304 |
Expansion tank material |
SUS304 |
Case material |
Steel channel + Square tube + Cold-rolled blanking plate painting |
-45°C~-10°C
Model |
ILRC-45-6W |
ILRC-45-10W |
ILRC-45-15W |
ILRC-45-20W |
ILRC-45-30W |
Temperature range °C |
-45°C~ -10°C |
||||
Cooling Capacity At -20°C |
12kW |
20kW |
30kW |
40kW |
60kW |
10320Kcal/h |
17200Kcal/h |
25800Kcal/h |
34400Kcal/h |
51600Kcal/h |
|
Cooling Capacity At -40°C |
6kW |
10kW |
15kW |
20kW |
30kW |
5160Kcal/h |
8600Kcal/h |
12900Kcal/h |
17200Kcal/h |
25800Kcal/h |
|
Circulation Pump |
6.6m³/h 2.5bar max |
9m³/h 2.5bar max |
15m³/h 2.5bar max |
15m³/h 2.5bar max |
25m³/h 2.5bar max |
Inlet & outlet connection size |
DN-25 PN-10 |
DN-25 PN-10 |
DN-32 PN-10 |
DN-32 PN-10 |
DN-40 PN-10 |
Water-cooled type W (cooling water at 30°C) |
8m³/h |
10m³/h |
16m³/h |
20m³/h |
25m³/h |
Cold storage tank (optional)
|
200L |
350L |
500L |
750L |
1000L |
Expansion Tank (standard) |
100L |
175L |
250L |
350L |
500L |
Compressor |
Standard: Copeland |
||||
Operation Panel |
7-inch color touch screen display, temperature curve record, data export to excel format. |
||||
Control system |
Standard: Single-chip microcomputer controller; Stepping control; Set temperature difference of refrigeration on & off. Optional: SIEMENS S7-200PLC&Module |
||||
Closed |
The whole system is a full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. |
||||
Circulation pump |
Standard: Direct type magnetic pump Optional: Increase the pipeline magnetic pump pressure in the pipeline |
||||
Evaporator |
Standard: Braze welding plate heat exchager (BPHE) Optional: Stainless steel tube heat exchanger |
||||
Condenser |
Shell and tube type water cooled condenser |
||||
Intermediate heat exchanger |
KAORI Plate heat exchanger |
||||
Dry Filter |
Emerson |
||||
Drying filter core |
Emerson |
||||
Expansion valve |
Emerson |
||||
FDF |
Emerson |
||||
Oil separator
|
Emerson |
||||
Pressure protector |
Emerson |
||||
Reservoir |
Standard: RSP Optional: Emerson |
||||
Sight glass |
Standard: SANHUA Optional: Danfoss |
||||
Refrigeration ball valve |
Standard: SANHUA Optional: Danfoss |
||||
Electric |
Schneider AC contactor, Schneider intermediate relay |
||||
Refrigerant |
R404A |
||||
Secondary refrigerant |
No corrosive liquid, ethanol water, ethylene glycol aqueous solution, heat transfer oil etc. |
||||
Safety protection |
High pressure protect; Water supply cut-off protection; Over-current protection; Leakage protection; Sequential and phase failure protection; High temperature protection; Sensor Failure protection; Liquid low level protection etc. muti-safety protection. |
||||
Level Indicator |
Adpot glass liquid level indication |
||||
Piping material |
SUS304 |
||||
Expansion tank material |
SUS304 |
||||
Case material |
Steel channel + Square tube + CoILRC-80-rolled blanking plate painting |
||||
Product size |
160*100*165 |
180*120*175 |
180*120*175 |
205*145*175 |
205*145*175 |
Power |
380V 50HZ 10kW max |
380V 50HZ 14kW max |
380V 50HZ 22kW max |
380V 50HZ 31kW max |
380V 50HZ 45kW max |
HP |
12HP |
15HP |
25HP |
35HP |
50HP |
dB |
Within 75dB |
Within80dB |
|||
Weight |
800kg |
950kg |
1100kg |
1350kg |
1500kg |
2
Model |
ILRC-45-40W |
ILRC-45-60W |
ILRC-45-90W |
ILRC-45-120W |
ILRC-45-180W |
Temperature range °C |
-45°C~ -10°C |
||||
Cooling Capacity At -20°C |
80kW |
120kW |
180kW |
240kW |
360kW |
68800Kcal/h |
103200Kcal/h |
154800Kcal/h |
206400Kcal/h |
309600Kcal/h |
|
Cooling Capacity At -40°C |
40kW |
60kW |
90kW |
120kW |
180kW |
344000Kcal/h |
51600Kcal/h |
77400Kcal/h |
103200Kcal/h |
154800Kcal/h |
|
Circulation Pump |
25m³/h 2.5bar max |
25m³/h 2.5bar max |
35m³/h 2.5bar max |
35m³/h 2.5bar max |
50m³/h 2.5bar max |
Inlet & outlet connection size |
DN-40 PN-10 |
DN-40 PN-10 |
DN-50 PN-10 |
DN-50 PN-10 |
DN-65 PN-10 |
Water-cooled type W (cooling water at 30°C) |
30m³/h |
38m³/h |
55m³/h |
70m³/h |
100m³/h |
Cold storage tank (optional)
|
1200L |
1500L |
2200L |
3000L |
4000L |
Expansion Tank (standard) |
600L |
750L |
1000L |
1350L |
1800L |
Compressor |
Standard: HANBELL screw compressor |
||||
Operation Panel |
7-inch color touch screen display, temperature curve record, data export to excel format. |
||||
Control system |
Standard: Single-chip microcomputer controller; Stepping control; Set temperature difference of refrigeration on & off. Optional: SIEMENS S7-200PLC&Module |
||||
Closed |
The whole system is a full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. |
||||
Circulation pump |
Standard: Direct type magnetic pump Optional: Increase the pipeline magnetic pump pressure in the pipeline |
||||
Evaporator |
Standard: Braze welding plate heat exchager (BPHE) Optional: Stainless steel tube heat exchanger |
||||
Condenser |
Shell and tube type water cooled condenser |
||||
Intermediate heat exchanger |
KAORI Plate heat exchanger |
||||
Dry Filter |
Emerson |
||||
Drying filter core |
Emerson |
||||
Expansion valve |
Emerson |
||||
FDF |
Emerson |
||||
Oil separator |
Emerson |
||||
Pressure protector |
Emerson |
||||
Reservoir |
Standard: RSP Optional: Emerson |
||||
Sight glass |
Standard: SANHUA Optional: Danfoss |
||||
Refrigeration ball valve |
Standard: SANHUA Optional: Danfoss |
||||
Electric |
Schneider AC contactor, Schneider intermediate relay |
||||
Refrigerant |
R404A |
||||
Secondary refrigerant |
No corrosive liquid, ethanol water, ethylene glycol aqueous solution, heat transfer oil etc. |
||||
Safety protection |
High pressure protect; Water supply cut-off protection; Over-current protection; Leakage protection; Sequential and phase failure protection; High temperature protection; Sensor Failure protection; Liquid low level protection etc. muti-safety protection. |
||||
Level Indicator |
Adpot glass liquid level indication |
||||
Piping material |
SUS304 |
||||
Expansion tank material |
SUS304 |
||||
Case material |
Steel channel + Square tube + CoILRC-80-rolled blanking plate painting |
||||
Product size |
235*145*175 |
245*145*205 |
350*150*205 |
350*150*205 |
450*200*205 |
Power |
380V 50HZ 61kW max |
380V 50HZ 86kW max |
380V 50HZ 127kW max |
380V 50HZ 167kW max |
380V 50HZ 247kW max |
HP |
70HP |
100HP |
150HP |
200HP |
300HP |
dB |
Within 90dB |
||||
Weight |
1800kg |
2400kg |
3100kg |
3600kg |
5000kg |